TRS-M Thermal Reed Switch
TRS-W Thermal Reed Sensor
- Switching range available from 25°C to 130°C with +/- 3°C tolerance
- Does not require external power for operation
- Normally closed (NC) contact
- For low level 10W loads
- Temperature differential of 10°C max
Applications
This thermal reed sensor is suitable for use in the following applications and in many others: overheat protection of power electronics, instant water heaters, deep freezers, coolers, and aquariums, radiator and engine temperature...
Specifications
Temperature tolerance |
°C |
+/-3 |
Contact Form |
|
B |
Contact Rating (max) |
W / VA |
10.0 |
Switching Current (max) |
A |
0.5 |
Carry Current (max) |
A |
1.0 |
Switching Voltage (max) |
V DC |
180 |
Switching Voltage (max) |
V AC |
130 |
Breakdown Voltage (min) |
V DC |
200 |
Initial Contact Resistance (max) |
mOhms |
150 |
Operating Temperature |
°C |
-20 to (cut out)+20 |
Ordering Code
TRS-W-(Cut out temperature in °C)-(Cable length in mm)-(Lead type)
Cut Out Temperature |
Lead Type |
25°C to 130°C |
S. Stripped to 5 mm |
|
T. Stripped to 5 mm and Tinned |
|
M. Molex Connector |
Example
TRS-W-50-500-M
TRS-W normally closed thermal reed sensor with a release of 50°C, having a 500 mm cable length and Molex connectors.